{"id":177,"date":"2024-12-07T22:06:02","date_gmt":"2024-12-07T14:06:02","guid":{"rendered":"http:\/\/hy1206.com\/?p=177"},"modified":"2026-07-14T10:53:15","modified_gmt":"2026-07-14T02:53:15","slug":"bit-1p2","status":"publish","type":"post","link":"https:\/\/www.ju-power.cn\/en\/genzongzhijia\/bit-1p2.html","title":{"rendered":"BiT-1P*2 TRACKER"},"content":{"rendered":"<p><span style=\"font-family: arial, helvetica, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-206 aligncenter\" src=\"https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/BiT-1P-2.png\" alt=\"\" width=\"483\" height=\"205\" srcset=\"https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/BiT-1P-2.png 483w, https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/BiT-1P-2-300x127.png 300w, https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/BiT-1P-2-18x8.png 18w\" sizes=\"auto, (max-width: 483px) 100vw, 483px\" \/><\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">The BiT-1P Dual is a single-vertical, double-row tracking bracket from Juzhiyi. It uses a single drive system to operate both rows of components in a coordinated manner, retaining the flexibility of a 1P single-row bracket while reducing the cost of foundations and drive systems to near the level of a 2P bracket. It is suitable for projects that desire the &quot;maintenance convenience of a 1P bracket + the economy of a 2P bracket&quot;.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><em>Why choose BiT-1P Dual?<\/em><\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>One drive unit drives two rows of components, resulting in a mechanical cost 25% lower than dual 1P units.<\/strong>The BiT-1P*2 system links two rows of 1P modules using a single rotary mechanism, requiring only one motor, one TCU, and one damper. Compared to the &quot;two independent 1P&quot; solution, the mechanical cost is reduced by approximately 25%, and the number of piles is also halved. For projects with relatively ample land but a desire to reduce CAPEX, this is a more favorable option than the 2P system.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Retaining the \u00b160\u00b0 tracking range of 1P, the power generation gain remains undiminished.<\/strong>Compared to BiT-2P&#039;s \u00b150\u00b0 tracking angle, BiT-1P*2 uses the \u00b160\u00b0 tracking angle of 1P, resulting in a wider solar tracking range. In low-latitude regions with strong radiation (Southeast Asia, the Middle East, and North Africa), this difference can increase annual power generation by 2%-3%.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Two rows of interconnected but structurally independent components offer more flexible component maintenance and cleaning compared to 2P systems.<\/strong>The BiT-1P*2 has an aisle between the two rows of components, allowing maintenance personnel to move between them. Single-sided component inspection does not require the removal of adjacent modules. Compared to the 2P&#039;s dual-row vertical integrated structure, the 1P*2 offers better maintenance accessibility, and the cleaning robot&#039;s working surface is also flatter.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Withstands wind speeds of 160 km\/h; key components made of Q550 high-strength steel.<\/strong>The entire unit passed the IEC 62817 standard wind tunnel test, and key structural components are made of Q550 high-strength steel (yield strength 550 MPa, higher than the 355 MPa of ordinary Q355). Combined with dampers and a TCU high-wind protection mode, the support structure automatically returns to its original level under extreme weather conditions.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><em>\u3010Typical Application Scenarios\u3011<\/em><\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Large-scale flat-ground power plants with relatively abundant land resources but requiring control of pile foundation and drive costs; sensitive to power generation gain (low-latitude areas with strong radiation); high requirements for module operation and maintenance accessibility; projects using bifacial modules.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-207 aligncenter\" src=\"https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/1P2.png\" alt=\"\" width=\"710\" height=\"658\" srcset=\"https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/1P2.png 724w, https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/1P2-300x282.png 300w, https:\/\/www.ju-power.cn\/wp-content\/uploads\/2024\/12\/1P2-13x12.png 13w\" sizes=\"auto, (max-width: 710px) 100vw, 710px\" \/><\/span><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>BiT-1P Dual \u662f\u805a\u4e4b\u4e49\u7684\u5355\u7ad6\u53cc\u6392\u8ddf\u8e2a\u652f\u67b6,\u628a\u4e24\u6392\u7ec4\u4ef6\u7528\u4e00\u5957\u9a71\u52a8\u8054\u52a8\u8fd0\u884c,\u65e2\u4fdd\u7559 1P \u7684\u5355\u6392\u7075\u6d3b\u6027, [&hellip;]<\/p>","protected":false},"author":1,"featured_media":206,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2],"tags":[],"class_list":["post-177","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-genzongzhijia"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/posts\/177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/comments?post=177"}],"version-history":[{"count":6,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/posts\/177\/revisions"}],"predecessor-version":[{"id":786,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/posts\/177\/revisions\/786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/media\/206"}],"wp:attachment":[{"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/media?parent=177"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/categories?post=177"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ju-power.cn\/en\/wp-json\/wp\/v2\/tags?post=177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}